BL (T) serie altzairu herdoilgaitzezko etapa anitzeko pila zentrifugoa (gero pump deritzona) eraginkortasun handiko, zarata gutxi, funtzionamendu egonkorra etab. Karaktereak ditu. Ponpa multzoak ez ditu berez lehengoratzeko bertikaleko etapa anitzeko egiturarik hartzen, Oso trinkoa, erraza da instalatzea, funtzionamendua eta mantentze egokia.
Water supply |
BL |
BLT |
Filtration and transfer at waterworks |
a- |
a- |
Distribution from waterworks |
a- |
a- |
Presio birsorkuntza sareetan |
a- |
a- |
Pressure boosting in high-rise buildins,hotels,etc. |
a- |
a- |
Pressure boosting for industrial water supply |
a- |
a- |
Industria |
|
|
Pressure boosting |
|
|
Process water systems |
a- |
a- |
Washing and cleaning systems |
a- |
a- |
Ibilgailuak garbitzeko tunelak |
a- |
a- |
Fire fighting systems |
a- |
a- |
Transferentzia likidoa |
|
|
Cooling and air-conditioning systems(refrigerants) |
a- |
a- |
Galdararen elikadura eta kondentsazio sistemak |
a- |
a- |
Makina erremintak (hozteko lubrifikatzaileak) |
a- |
a- |
Aquafarming |
a- |
a- |
Transfer |
|
|
Olioa eta alkohola |
a- |
a- |
Glycol eta hozgarriak |
a- |
a- |
Water treatment |
|
|
Ultra filtrazio sistemak |
a- |
a- < |
Alderantzizko osmosi sistemak |
a- |
a- < |
Berotzea, ionizatzea, desmineralizatzeko sistemak |
a- |
a- < |
Distillation sys tems |
a- |
a- < |
Separators |
a- |
a- < |
Igeriketa bainuak |
a- |
a- |
lrrigation |
|
|
Field irrigation(flooding) |
a- |
a- |
Sprinkler irrigation |
a- |
a- |
Drip irineko ureztatzea |
a- |
a- |
Energia Eraginkortasunaren Estandarra (IEC60034)
Gutxieneko sarrera presioaren kalkulua
Ponpa presioa euskarriaren presioaren presioa baino txikiagoa bada, zuntzek eragingo dute ponpa errendimenduan. Cavitation saihesteko eta pump sarrerako presio gutxieneko bat du, gehienezko xurgatze burua kalkulatu behar da honako hau:
H = Pbx10.2-NPSH-HF-hv-Hs
Pb: Presio atmosferikoa, barra (kanalizazio itxi batean, sistema presio gisa hartu daiteke);
NPSH: Xurgatze posizio garbia, m (Balioa Q-NPSH kurba maximoa balioa);
Hf: Suction pipa linearen galera (dagokion kanalaren fluxuaren gehienezko balioa);
Hv: Medium vapour pressure, m (Medium vapour pressure at corresponding temperature, the default medium is water, as shown in figure4 on the right );
Hs: Safety margin, m, general value is 0.5.
Calculation result: if H is positive, the pump is installed in suction way, otherwise, it is installed in downdraft way.
Oharra: ez da beharrezkoa goiko kalkulua egiteko baldintza orokorretan. Ponpa erabiltzen dugunean hurrengo egoeretan, H kalkulatu behar dugu:
1. Tenperatura ertaina altua da;
2. Fluxuaren abiadura balioa baino handiagoa da;
3.Sukulua buru handia da edo sarrera kanalizazioa luzea da;
4. Sistema presioa txikiegia da.
5.Inlet condition is bad.
Selection Of Pumps
Selection of pumps should be based on:
Ponpa puntua.
Datu dimentsionalak, esate baterako, presioaren galerak, altuera desberdintasunen arrasate gisa, kanalizazioan marruskadura galera,
Ponpa eraginkortasuna, etab.
Pump materials
Pump connections
Ohiko erabilitako seal konfigurazio taulak
1. Ponpa puntuala:
From a duty point it is possible to select a pump on the basis of the curve charts shown in "performance curves/technical" data.2. Dimentsio datuak:
When sizing a pump the following must be taken into accounting: •Required flow and pressure at the draw-off point. •Pressure loss as a result of height differences. •Friction loss in the pipework(Hf) (Refer to Fig.1) It may. •Best efficiency at the estimated duty point. •NPSH value. •For calculation of the NPSH value, see corresponding curves chart.3. Pump efficiency:
Eraginkortasun-punturik onena zehaztu aurretik, ponpa funtzionamendua identifikatu behar da. Pump funtzionamendua betebeharra berbera gisa espero zen, eta, ondoren, hautatu BL pump ponpak eraginkortasun onena dagokion betebeharra puntuan funtzionatzen.As the pump is sized on the basis of the highest possible flow, it is important always to have the duty point to the right on the efficiency curve(eta) in order to keep efficiency high when the flow drops.
4. Ponpa materiala:
Pump konexioaren aukeraketa presio eta kanalizazioko lanen araberakoa da. Ponpa konexio erraztasuna zabala eskaintzen du, hala nola:
5. Ohiko erabilitako seal konfigurazio taulak
Aplikazioen eremua | Shaft seal mota | Shaft seal materiala | ||||||||||
normal | Special | 1 | 2 | 3 |
4
5
|
Type key | ||||||
Rotating part | Kodea | Papergintza | Kodea | elastomeroak | Kodea | Compression spring | Collor | Kodea | ||||
0℃ to +90℃ clean water | a- | Graphite | A | SiC | S | FPM | F | SUS304 | C | ASFC | ||
0℃ to +90℃ clean water | a- | Komunak | W | Graphite | A | FPM | F | SUS304 | C | WAFC | ||
+ 90â "ƒ to + 120â" ƒ korrosioarekiko erresistentzia | a- | SiC | S | SiC | S | EPDM | E | SUS304 | C | SSEC | ||
0ra arte "ƒ | a- | Komunak | W | Komunak | W | EPDM | E | SUS304 | C | WWEC |
Mechanical seal type | Pump model | d1 | d2 | h |
NJK | BL(T)2/4 | 12 | 12 | 55 |
BL(T)8/12/16/20 | 16 | 16 | 57.5 | |
BL(T)32/45/60/90 | 22 | 22 | 72 | |
NDA | BW (J) 2/4 | 12.7 | 16 | 32 |
BW (J) 8/16 | 17.4 | 20 | 33,5 |
Model |
Curve No. |
BL (T) 2,4 |
2 |
BL (T) 8,12,16,20 |
3 |
BL(T)32-2-2~BL(T)32-7 |
1 |
BL (T) 32-8-2 ~ BL (T) 32-12 |
4 |
BL(T)32-13~BL(T)32-15-2 |
5 |
BL (T) 45-2-2 ~ BL (T) 45-6 |
1 |
BL(T)45-7-2~BL(T)45-9 |
4 |
BL (T) 45-10-2 ~ BL (T) 45-13-2 |
5 |
BL(T)64-2-2~BL(T)64-5-2 |
1 |
BL(T)64-5-1~BL(T)64-8 |
4 |
BL (T) 90-2-2 ~ BL (T) 90-4-2 |
1 |
BL(T)90-4~BL(T)90-6 |
4 |
BL(T)120,150 |
6 |

Presioaren eta tenperaturaren mugak hurrengo irudian agertzen dira4, presioa eta tenperatura figuran agertzen dira. 4.
40 ºC-tik gorako tenperaturaren tenperatura 40 ºC baino altuagoa denean edo altitudea 1000 metro baino handiagoa bada, potentzia-potentzia P2-ko potentzia irteera gutxituko da airearen dentsitate baxuko eragindako hozte txikia dela eta. Beraz, kasu horretan ponpa Potentzia handiko motorra behar da.


Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
Igogailuaren barrutian erabil daiteke.
PN25-40 / DN100 estandar flange, eskatuta.
Igogailuaren barrutian erabil daiteke.
PN25-40 / DN100 estandar flange, eskatuta.
Igogailuaren barrutian erabil daiteke.